Residential Ventilation

Residential ventilation is a coordinated family of local extract, fresh-air, balanced and energy-recovery solutions. RAFAVENT selects each path by airflow, resistance, acoustics, controls and documented supply scope.

Local extract & compact duct fans

Bathroom, WC, utility, kitchen-support and inline extract duties with backdraft and duct-resistance allowance.

Fresh-air & balanced systems

Filtered outdoor-air supply or coordinated supply/extract with room-pressure and control strategy defined by the project.

Central, roof & HRV/ERV solutions

Apartment central exhaust, residential roof fans and heat/energy recovery units only within an exact documented proposal.

Residential ventilation product paths

Product pathTypical airflow envelopePressure envelopePrimary selection criteriaPublication status
Bathroom / service extract50–350 m³/h30–180 PaSound, backdraft protection, humidityExact model data required
Compact inline duct fans100–1,000 m³/h50–500 PaDuct resistance, access, speed controlCross-reference Inline Duct Fans
Fresh-air units100–1,500 m³/h100–600 PaFilter ΔP, outdoor condition, soundProject-specific configuration
Balanced supply & extract150–2,000 m³/h100–650 PaAir balance, controls, commissioningProject-specific configuration
HRV / ERV units150–2,000 m³/h100–650 PaCertified recovery data, leakage, frost/condensateOnly with exact supplier/unit documentation
Central / residential roof extract500–5,000 m³/h100–700 PaRiser resistance, fire strategy, roof terminationProject-specific; code review required

Air-path and installation allowances

ItemEngineering allowance
Duct routeStraight length, elbows, transitions and flexible duct
TerminalsGrilles, valves, louvers and weather hoods
ProtectionBackdraft damper, insect screen and rain protection
FiltrationFilter class and clean/final pressure drop when applicable
AcousticsRoom target, breakout noise, duct-borne noise and attenuation
MaintenanceAccess, cleaning, filter replacement and condensate management

Controls and operating modes

ModeRequirement
Basic controlOn/off or switched with room service
Speed controlOnly with a compatible motor/controller combination
Demand controlHumidity, CO₂, occupancy or timer sensor as project option
Boost modeDefined high-speed duty and run-on period
BMS interfaceDry contact, 0–10 V or protocol only when documented
Electrical safetyIsolation, protection and wiring coordinated to local rules

Available fan pressure ≥ duct + fittings + terminals + dampers + filters (clean/final) + project reserve

Required project data

InputRequired detail
Air dutyRequired airflow and external static pressure at each mode
Design basisRoom volume, occupancy and required ventilation rate from the governing code
EnvironmentTemperature, humidity, grease, lint, corrosive content and outdoor exposure
InstallationWall/ceiling/duct position, connection size, route and access
SoundMaximum room and external sound target at the stated distance
Supply scopeFan, terminals, filters, dampers, controls and commissioning requirement

RAFAVENT
Engineering boundary: Published values are preliminary calculated, non-certified selection envelopes. Final airflow must be checked against the complete duct resistance. Ventilation rates, indoor-air-quality outcomes, heat-recovery efficiency, acoustic performance and regulatory compliance are not implied and require the exact selected equipment, governing local code and project evidence.