RAFAVENT

High-Efficiency & Inverter-Controlled Fans

Published product and engineering information

RAFAVENT VARIABLE-SPEED VENTILATION

High-Efficiency & Inverter-Controlled Fans

Project-selected fan, motor and variable-frequency-drive arrangements for ventilation systems with changing duty. Performance and efficiency statements apply only to the exact documented fan–motor–drive package selected for the project.

Technical boundary: A variable-frequency drive controls motor speed and can reduce input power when the required duty is lower. It does not by itself make a fan high-efficiency. The result depends on the fan and impeller, motor, operating point, drive settings and system resistance.

Available system arrangements

Axial fan + VFD

Variable-speed axial arrangements selected for airflow, pressure, installation limits, acoustics and the required control method.

Centrifugal or plug fan + VFD

Pressure-oriented arrangements for ducted, filtration, air-handling and industrial ventilation duties.

Inline, roof or custom fan + VFD

Project-specific packages selected around the actual duty point, installation environment and electrical requirements.

What inverter control can provide

  • Variable fan speed within the approved operating range
  • Soft starting and controlled acceleration or deceleration
  • Pressure or airflow regulation when suitable sensors and controls are specified
  • BMS interface where the selected VFD and project documents support it
  • Closer matching of fan output to changing system demand

Required project schedule

Required fieldProject definition
Duty pointsMinimum, normal and maximum airflow with corresponding static or total pressure
Fan arrangementAxial, centrifugal, plug, inline, roof or custom configuration
Motor dataRated power, speed, efficiency class when documented, insulation and service conditions
Electrical supplyVoltage, phase, frequency and available fault level
VFD sizingMotor current, overload duty, ambient temperature, enclosure and derating conditions
Control methodManual setpoint, 0–10 V, 4–20 mA, pressure/airflow loop or documented BMS protocol
Installation limitsIP rating, ambient conditions, cable length, EMC, harmonics and ventilation of the drive
Special dutyBypass, emergency operation, smoke-control, high-temperature or hazardous-area requirements

Efficiency approach

  • Select the fan close to an efficient operating region for the required duty.
  • Use a suitable high-efficiency motor where its class and availability are documented.
  • Define minimum and maximum permitted speed and any resonance exclusion bands.
  • Commission the fan, motor, VFD and control loop as one system.
  • Confirm final performance from the selected equipment documents and project testing requirements.

Application limits

No certified fan efficiency, energy saving or acoustic value is claimed without documented selection data. Smoke-control, high-temperature, explosion-risk and other safety-critical duties require a compatible and documented fan, motor and drive arrangement. One VFD is normally assigned to one motor unless a specifically engineered multi-motor scheme is approved.

Selection and release process

  1. Define airflow, pressure and all scheduled operating points.
  2. Confirm installation, electrical supply, control and environmental requirements.
  3. Select the fan, motor and VFD as a coordinated package.
  4. Review operating range, input power, acoustics, resonance and protection.
  5. Issue the project-specific performance, wiring and control documents.
Send inverter-controlled fan project data