English

RAFAVENT ENERGY-EFFICIENT VENTILATION

EC & High-Efficiency Fans

Project-selected EC fan modules and high-efficiency motor/VFD arrangements for variable-duty ventilation. Electrical and efficiency claims apply only to the exact selected fan-motor-control package.

Technical boundary: EC technology does not by itself define complete-fan efficiency. Motor class, input power, fan efficiency, control protocol, protection and energy comparison are stated only from the selected product documentation and duty point.

Available system arrangements

EC centrifugal / plug-fan module

Backward-curved module with integrated EC electronics where supported by the selected manufacturer.

EC axial / inline module

Variable-speed axial or inline assembly selected for airflow, pressure, acoustics and installation.

High-efficiency AC motor + VFD

Conventional fan with documented high-efficiency motor and matched inverter; system efficiency verified at duty.

Required electrical and control schedule

Required fieldProject definition
Motor / drive typeEC integrated drive or AC motor with VFD
SupplyExact voltage, phase, frequency, current and input power
Control input0–10 V, PWM, enable contact or other documented input
CommunicationModbus RTU/BACnet/alarm output only where provided by selected unit
ProtectionIP rating, thermal overload, locked-rotor, phase and undervoltage functions
FeedbackSpeed, status, alarm, power or temperature only when documented
Operating limitsAmbient temperature, altitude, humidity, EMC and harmonic requirements
Efficiency evidenceMotor class, fan efficiency and complete package input power kept separate
CommissioningMinimum speed, resonance exclusion, ramp, setpoint and fail-safe behaviour

Preliminary model performance

Calculated selection data — non-certified. Variable speed is available only within the selected motor/fan limits; final input power and efficiency require model-specific documentation.

ModelConnectionAirflow m³/hStatic pressure PaSpeedMotor kWSupplyEst. dB(A) @ 3 m
RF-EC-250250 mm400–1,00080–250Variable0.251Ph42
RF-EC-400400 mm1,500–4,000150–500Variable1.51Ph / 3Ph54
RF-EC-560560 mm3,500–9,000250–850Variable43Ph64
RF-EC-710710 mm6,500–16,000350–1,200Variable7.53Ph72

Calculated full-speed reference curves

RF-EC-250

Airflow m³/hStatic pressure Pa
#Airflow m³/hStatic pressure Pa
10250
2200248
3400235
4600205
5800145
61,0000

RF-EC-400

Airflow m³/hStatic pressure Pa
#Airflow m³/hStatic pressure Pa
10500
2800495
31,600470
42,400410
53,200290
64,0000

RF-EC-560

Airflow m³/hStatic pressure Pa
#Airflow m³/hStatic pressure Pa
10850
21,800842
33,600799
45,400697
57,200493
69,0000

RF-EC-710

Airflow m³/hStatic pressure Pa
#Airflow m³/hStatic pressure Pa
101,200
23,2001,188
36,4001,128
49,600984
512,800696
616,0000

Selection and release process

  1. Define airflow, pressure and all operating points across the schedule.
  2. Confirm supply, control signal, BMS protocol, alarm and feedback requirements.
  3. Select the exact fan, motor/EC electronics and protection features.
  4. Verify input power, efficiency, acoustics, resonance and part-load operation.
  5. Issue wiring, control and performance documents for the selected package.

Request an engineering selection

Send the duty point, installation arrangement, operating conditions and available drawings for a project-specific selection.

Send project requirements