English

MEP Support Systems

RAFAVENT Support Profile and strut-channel systems for HVAC ducts, piping, cable trays and coordinated building services. Every arrangement is selected from the actual load path, span, substrate and environment.

Trapeze & ceiling supports

Single- or multi-profile suspended frames for ducts, pipes and cable routes.

Wall, floor & equipment frames

Brackets, cantilevers, bases and modular frames for plantrooms and service zones.

Coordinated multi-service supports

Shared assemblies engineered around combined loads, clearances, movement and installation sequence.

Coordinated product range

Product groupArrangementControl note
Support Profiles / strut channelsSingle or back-to-back sectionsSize, thickness, grade and finish per controlled datasheet
Brackets and cantileversWall, ceiling and frame connectionsCapacity depends on geometry, fixing and load direction
Base plates and connectorsFrame nodes and structural interfacesCheck plate, bolts, welds and eccentricity
Channel and spring nutsProfile connectionsThread, engagement and compatibility must match
Threaded rods and accessoriesSuspended supportsDiameter, grade, length, buckling and rod bracing
Pipe / duct / beam clampsService and structure connectionDiameter, lining, temperature and base interface
Anchors and fastenersConcrete, steel or approved substrateExact anchor approval and installation parameters required

Mandatory engineering inputs

InputRequired definition
Service loadsEmpty, operating, insulated, fluid and point loads
Support geometrySpan, cantilever, drop, eccentricity and member orientation
Load casesDead, imposed, thermal, vibration, wind and maintenance loads
SubstrateConcrete strength, steel grade, edge distance, embedment and access
EnvironmentIndoor/outdoor, moisture, chemical exposure and corrosion category
MovementThermal expansion, flexible points, guides and anchors
Special requirementsSeismic, fire, acoustic or fatigue requirement only when specified

Required verification checks

CheckEngineering requirement
MembersBending, shear, interaction, local effects and utilization
DeflectionProject serviceability limit at operating load
ConnectionsBolts, channel nuts, plates, welds and slip resistance
Threaded rodsTension, combined action, unbraced length and buckling where relevant
AnchorsTension/shear interaction, concrete condition, edge/group effects
Load pathContinuous transfer from service to primary structure
CompatibilityCoating, galvanic contact, temperature and manufacturer interfaces

Controlled project deliverables

DeliverableControlled content
Selection basisCodes, load assumptions, safety factors and exclusions
Support scheduleTag, arrangement, span, components and quantities
DrawingsTypical details and project-specific coordinated locations
BOM / BOQProfiles, plates, rods, clamps, nuts, anchors and fasteners
Product evidenceDatasheets, material/finish declarations and applicable approvals
Calculation noteIssued only when included and reviewed within project scope
Installation / inspectionTorque, embedment, spacing, field changes and acceptance records

RAFAVENT
Engineering boundary: No universal allowable-load table applies to every Support Profile arrangement. Capacity depends on section, thickness, material grade, span, orientation, connection, anchor, substrate and load case. Structural, seismic, fire-resistance, corrosion-life or equivalence claims apply only when supported by the exact approved product and project documentation.

Need engineering support?

Send the required airflow, pressure, operating conditions, installation constraints and available project documents. RAFAVENT will review the information before proposing a suitable configuration.

Request Engineering Review

Performance Curve

Engineering status: Not applicable to structural support products. Engineering output is expressed through load capacity, utilization, deflection and connection checks rather than an aerodynamic curve.

Dimensions

Profile size, span, cantilever, drop, rod length, plate geometry, fixing centres and coordinated service clearances are defined on the support schedule and project drawings.

Construction & Materials

Profile and plate grade, thickness, rods, channel nuts, anchors, bolts, welds and protective finish are specified for the loads, substrate and corrosion environment.

Drive Arrangement

No drive arrangement applies. The equivalent controlled interface is the load path from supported services through members, connections and anchors to the building structure.

Technical Documentation

Selection basis, calculation sheet, support schedule, coordinated drawings, BOM/BOQ, material and finish declarations, installation details and approved product evidence are controlled deliverables.