RAFAVENT

Tunnel Jet Fans

Product overview

Longitudinal tunnel-ventilation fans engineered around required jet thrust, air velocity, tunnel geometry and operating strategy. RAFAVENT tunnel jet-fan construction is available from Ø560 to a maximum family size of Ø1400.

← Back to Jet & Smoke-Control Fans

Required installed thrust in newtons, traffic direction, tunnel cross-section, spacing and permissible air velocity.

Ceiling clearance, wall proximity, silencers, mounting cradle, obstructions and cross-flow can reduce effective installed thrust.

Unidirectional or reversible airflow, normal ventilation, emergency strategy, VFD control and redundancy philosophy.

Nominal thrust is calculated from air momentum at standard-density air (approximately 1.2 kg/m³). Use installed-thrust correction factors during detailed design.

Six-point speed-law presentation at 0%, 25%, 50%, 75%, 90% and 100%: airflow varies approximately with speed, thrust with speed² and absorbed power with speed³. Displayed thrust is rounded to the nearest newton and power to 0.1 kW. Values are preliminary and exclude installation corrections.

RAFAVENT has developed a pressure-loaded Ø1400 tunnel axial arrangement with inlet/outlet silencers and downstream guide vanes. This reference is distinct from the generic free-jet thrust ratings above.

Rolled, flanged heavy-gauge steel casing

Project-specific corrosion-protection coating

Aerodynamic impeller with adjustable design pitch

External terminal box and protected cable routing

Inlet and outlet attenuators sized to the duty

Mounting cradle, feet or ceiling suspension arrangement

https://rafavent.com/tunnel-jet-fans/
2026-09-05