Technical document centre

Technical datasheet

Verified construction and selection fields

Performance curves

Airflow and pressure data by confirmed model

Dimensions & CAD

Installation dimensions and available CAD files

Catalogue PDF

Controlled catalogue release for this subfamily

Compliance documents

Only certificates applicable to the supplied configuration

Installation & O&M

Installation, operation and maintenance instructions

Controlled document status

  • Technical Datasheet — Available after model selection
  • GA Drawing — Project-specific
  • Performance Curve — Preliminary data available on page; controlled curve after selection
  • CAD — On request after engineering review
  • Installation & O&M — Issued with approved supply
  • Compliance Documents — Only where applicable to the supplied configuration

Preliminary axial roof-fan selection

Calculated catalogue guidance for high-airflow, low-pressure roof extraction. Final duty, sound, curb, weather hood, backdraft damper and motor are confirmed in the approved submittal.

ModelImpeller (mm)Max airflow (m³/h)Reference static pressure (Pa)Motor estimate (kW)
RF-RF-A-2502502,4001800.18
RF-RF-A-3153154,2002200.37
RF-RF-A-3553556,0002400.55
RF-RF-A-4004008,2002800.75
RF-RF-A-45045011,0003001.1
RF-RF-A-50050014,5003401.5
RF-RF-A-56056019,0003802.2
RF-RF-A-63063025,5004203
RF-RF-A-71071033,0004504
RF-RF-A-250 — Calculated Q–Ps curve
Airflow (m³/h)Static pressure (Pa)
0180
600169
1200137
180077
24000
RF-RF-A-315 — Calculated Q–Ps curve
Airflow (m³/h)Static pressure (Pa)
0220
1050207
2100167
315095
42000
RF-RF-A-355 — Calculated Q–Ps curve
Airflow (m³/h)Static pressure (Pa)
0240
1500226
3000182
4500103
60000
RF-RF-A-400 — Calculated Q–Ps curve
Airflow (m³/h)Static pressure (Pa)
0280
2050263
4100213
6150120
82000
RF-RF-A-450 — Calculated Q–Ps curve
Airflow (m³/h)Static pressure (Pa)
0300
2750282
5500228
8250129
110000
RF-RF-A-500 — Calculated Q–Ps curve
Airflow (m³/h)Static pressure (Pa)
0340
3625320
7250258
10875146
145000
RF-RF-A-560 — Calculated Q–Ps curve
Airflow (m³/h)Static pressure (Pa)
0380
4750357
9500289
14250163
190000
RF-RF-A-630 — Calculated Q–Ps curve
Airflow (m³/h)Static pressure (Pa)
0420
6375395
12750319
19125181
255000
RF-RF-A-710 — Calculated Q–Ps curve
Airflow (m³/h)Static pressure (Pa)
0450
8250423
16500342
24750194
330000

Information required before selection

  • Required airflow and static pressure
  • Operating temperature and conveyed-air composition
  • Installation orientation, space and connection details
  • Electrical supply, control method and duty pattern
  • Sound, material and environmental constraints

Request an engineering selection

Send the duty point, installation arrangement, operating conditions and available drawings for a project-specific selection.

Send project requirements